{"product":{"productId":"agid.24346","price":94.34,"name":"Status sensors, stainless steel with bracket for toggle clamps"},"currency":"EUR"}
Matière
Stainless steel
Finition
Bright.
Afficher plus
Afficher moins
Status sensors, stainless steel with bracket, Form H, for horizontal toggle clamps
à partir de
94,34 €
hors TVA
hors frais d’envoi
Status sensors, stainless steel with bracket, Form V, for vertical toggle clamps
à partir de
94,34 €
hors TVA
hors frais d’envoi
Description
Description du produit
Status sensors with brackets are used to monitor the actuated status of toggle clamps.
The sensor detects whether the toggle clamp is open or closed and enables this status information to be processed electronically.
The sensor is attached to the toggle clamp via the bracket.
The sensor detects whether the toggle clamp is open or closed and enables this status information to be processed electronically.
The sensor is attached to the toggle clamp via the bracket.
Matière
Stainless steel
Finition
Bright.
Nota
The status sensor and brackets are supplied unassembled.
Données techniques
Inductive sensor:
Output relay: PNP normally open (NO)
Operating voltage: 10 - 30 V DC
Operating current: 100 mA
Switch gap: 0.8 mm
Switching frequency: 5000 Hz
Short-circuit proof: yes
Reverse polarity protected: yes
IP rating: IP 67
Connection type: 0.3 m cable, PUR, with plug
Temperature range: -25° C - +70°C
Approvals: CE, c-UL-us, UKCA, WEEE
Output relay: PNP normally open (NO)
Operating voltage: 10 - 30 V DC
Operating current: 100 mA
Switch gap: 0.8 mm
Switching frequency: 5000 Hz
Short-circuit proof: yes
Reverse polarity protected: yes
IP rating: IP 67
Connection type: 0.3 m cable, PUR, with plug
Temperature range: -25° C - +70°C
Approvals: CE, c-UL-us, UKCA, WEEE
Plage de température
Temperature range: -25 °C to +70 °C
Montage
The status sensor is fastened to the bracket with the nuts and set to dimension L1.
The bracket is attached with the toggle clamp screws through holes between the foot and the mounting surface.
The switch point fine-tuning is carried out once the toggle clamp is mounted.
The detailed procedure is described in the assembly instructions.
The bracket is attached with the toggle clamp screws through holes between the foot and the mounting surface.
The switch point fine-tuning is carried out once the toggle clamp is mounted.
The detailed procedure is described in the assembly instructions.
Sécurité
Status sensors are not suitable for protecting people.
Indication de dessin
1) LED-indicator
BN = brown
BK = black
BU = blue
BN = brown
BK = black
BU = blue